CompressorLynx®
Overview
CompressorLynx compressor shutdown alarming
CompressorLynx uses the SMS4D discrete alarming device and SMS "store and
forward" technology to transmit a compressor shutdown alarm to the eLynx Data
Center. Once the alarm is received at the eLynx Data Center (usually within
seconds), the eLynx system issues simultaneous email or pager messages to
multiple personnel reporting on the location and nature of alarm.
The CompressorLynx / SMS4D utilizes the existing cellular communications
infrastructure, in particular GSM technology, to transport remote status changes
using SMS messaging. Once a status change is detected on one of the four inputs,
the device “wakes up”, and the 10 second de-bounce timer begins counting down.
If the input does not transition back to its previous state before the timer
expires, an alarm message is sent directly to the eLynx data center. Once the
alarm message is received, an automatic process immediately identifies the unit
by its embedded ten-digit ID number. The entire message is then parsed, and
alarm notifications are forwarded to all entries in the customer's notification
list for that specific input. The change of status is simultaneously updated to
the customer's web. The entire process typically takes less than one minute.
Additional browser-based tools provide our clients with the following data:
- Status (down or normal)
- Last 7 days run time percentage
- Month to date run time percentage
- Real-time alarm notification
- Down hours
- Run hours
- Drill downs that provide you with alarm history duration and device data history
Benefits
- Wireless communications utilizing existing infrastructure (no need to install
towers, phone lines, obtain radio licenses, etc.)
- Coverage throughout the U.S., Canada, Mexico, and parts of South America
- Low cost of ownership
- Dependable service
Specifications
Physical:
- Size: 6.50" L x 3.45" x 1.25" H
- Weight: < 1.0 lb.
- Lights: 1 LED with blink patterns to indicate
- Power
- Alarm
- Signal
- Registration
- Connectors
- Power - Phoenix PCB D/Is 1 - 4 Phoenix PCB
- Programming 1/8" 3 conductor phono tip
- Radio - SMA Female Temperature: -30 C to +60 C
- Temperature: -30C to +60C
Electrical:
- Input voltage: 9 - 24 VDC
- Idle: < 250 micro amps @13.5 VDC
- Transmit: < 1 amp (instantaneous)
The CompressorLynx package is shipped with its own solar panel and battery power
package and a communication device for connection back to the compressor.
Download the
CompressorLynx Data Sheet.